Cyclic AMP (cAMP) Activity Fluorometric Assay (TBS2081)

$490.00

SKU: TBS2081 Category:
SKUStock SIZE (test) PriceQuantity
TBS2081-100 Yes 100 Tests $490.00
spinner

Description

This assay kit is a competition enzyme-linked immunoassay designed to measure cAMP levels in cells or tissues. An anti-mouse IgG was pre-coated onto a microplate. The cAMP in the test sample competes with HRP-cAMP for binding to an anti-cAMP mouse monoclonal antibody. Following the incubation and wash step, an ultra-sensitive HRP fluorescence substrate is added to generate fluorescence can be measured at excitation 535 nm and emission at 585 nm. Because of the competitive nature of this assay, the fluorescent intensity is inversely proportional to the quantity of sample cAMP. Measurement using the cAMP Standard allows calculating the absolute amount of cAMP in a sample. This assay is more sensitive than a colorimetric assay.

Typical Data

This standard curve is provided for demonstration only. A standard curve should be generated for each set of samples assayed. Fig. 2 is an example of typical Data.

Sensitivity

The minimum detectable dose (MOD) of cAMP is typically 1 nM.

The Intra-assay CV and the Inter-assay CV are ˂10%.

Specificity

This assay recognizes cAMP. No cross-reactivity with others.

 

Standard Preparation

 

Standard Curve

 

Kit Content and Storage Conditions

Part Part# Description Storage of Opened/Reconstituted
Precoated Microplate TBS2081A 96 well polystyrene microplate (12 strips of 8 wells) coated with anti-mouse IgG antibody. Return unused wells to the foil pouch. Reseal along the entire edge of the zip-seal. May be stored for up to 1 month at 2-8 °C.
cAMP Standard TBS2081B 50 µL of cAMP (1 mM). Aliquot and store at -20 ℃ for up to 1 month in a manual defrost freezer. Avoid repeated freeze-thaw cycles.
Detection A TBS2081C 100 µL of cAMP-HRP (25x). Store at 4℃ for 3 months
Detection B TBS2081D 1 mL of anti-cAMP antibody (5x). Store at -20℃ for 12 months.
Assay Diluent TBS2081E 15 mL of a buffered protein base with preservatives. Store at 4℃ for 12 months.
HRP Fluorescent Substrate TBS2081F 12 mL of ultra-sensitive fluorescent substrate. Store at -20℃ for 12 months.
Substrate Developer TBS2081G 20 µL Store at 4℃ for 12 months.
Wash Buffer TBS3000W 12 mL of concentrated solution (10x)

Store the unopened kit at 2-8 ℃. Do not use past kit expiration dates.
The kit contains sufficient materials to run an ELISA on one 96-well plate.

Additional information

SIZE (test)

100 Tests

Reviews

There are no reviews yet.


Be the first to review “Cyclic AMP (cAMP) Activity Fluorometric Assay (TBS2081)”